Specialised Power Hardware

Custom Transformers for Data Centres UAE

Purpose-built isolation, cast resin, and power transformers for UAE data centres — supplied by King Link Electrical Trading LLC (our specialist sister company), commissioned and BMS-integrated by Intellicon. Up to 2 MVA, K-20 harmonic rated, custom voltage configurations.

Get a Specification QuoteKing Link Transformers ↗
2 MVA
Max Rating
K-20
Harmonic Rating
5 Types
Transformer Categories
2–4 wks
Typical Lead Time
BMS
Modbus/BACnet Monitoring
🤝
Supplied by King Link Electrical Trading LLC

King Link Electrical Trading LLC is our UAE-based sister company, ISO 9001:2015 certified, specialising in custom-manufactured power hardware including transformers, voltage stabilisers, and load banks for industrial, commercial, and data centre applications across the UAE. All hardware supplied by King Link is commissioned and BMS-integrated by Intellicon's controls engineering team — one point of accountability from hardware to software.

kinglinkdubai.com ↗
Product Range

5 Transformer Types for Data Centres

Each type serves a specific function in the data centre power chain. Specifying the wrong type wastes capital and leaves equipment unprotected.

🛡️

Isolation Transformers

Up to 2 MVA
K-13 / K-20 harmonic rated | Electrostatic shields | Custom voltage configurations

Electrically separates the primary supply from the IT load, eliminating common-mode noise, ground loops, and conducted interference from the supply network. K-20 harmonic rating accommodates the high harmonic current content generated by thousands of server switching power supplies without insulation overheating.

Applications
  • Server rack PDU feeds
  • UPS input circuits
  • Data centre main distribution
  • Medical imaging power supply
🏗️

Cast Resin Dry-Type Transformers

50 kVA – 2 MVA
IP31+ | No oil | Class F insulation | Indoor rated | Custom HV/LV configurations

The standard for indoor data centre power distribution. Resin encapsulation eliminates oil fire risk (zero oil), passes F1 fire class test, and provides superior moisture immunity compared to conventional air-cooled dry types. Available in 11kV, 6.6kV, 3.3kV primary configurations for direct connection to DEWA HV supply.

Applications
  • Main HV/LV step-down
  • Indoor substations
  • Data hall power distribution
  • Hospital electrical rooms

Power Transformers

Up to 2 MVA
Custom voltage ratings | Oil-cooled or dry | Low-loss core design

Heavy-duty industrial power transformers for data centre campus incoming supply, generator interface, and utility interconnection. Manufactured with low-loss silicon steel cores for minimum no-load losses — critical in facilities that run 24/7 at varying load profiles.

Applications
  • Utility interconnection
  • Generator step-up/down
  • Campus power distribution
  • Industrial plant supply
🔁

Auto Transformers

Up to 2 MVA | Up to 11kV
Single / Three phase | Buck-boost configurations | Compact footprint

Cost-effective voltage matching for imported data centre equipment rated for 208V, 480V, or 575V connected to UAE 415V/230V supply. Also used for soft-start motor applications and UPS output voltage trimming.

Applications
  • 208V/480V equipment matching
  • UPS voltage adjustment
  • Imported machinery compatibility
  • Motor soft-start circuits
🔬

Control Transformers

Up to 50 kVA | Up to 690V
Class F insulation | Copper wound | Custom output voltages

Dedicated voltage supply for BMS controllers, PLC panels, and automation control circuits. Isolates sensitive control electronics from the main power distribution, preventing voltage transients from generator switching or UPS transfers from resetting BMS controllers at critical moments.

Applications
  • BMS and DDC panels
  • PLC control cabinets
  • Data centre automation
  • UPS bypass control circuits

Technical Specifications

Max Rating2 MVA
Primary Voltage415V / 3.3kV / 6.6kV / 11kV
Secondary VoltageCustom — 415V, 230V, 208V, 110V, 48V
CoolingAN (dry), ONAN (oil), ONAF (forced)
Harmonic RatingUp to K-20
EnclosureIP21 – IP54 custom enclosures
StandardsIEC 60076, BS EN 61558, BSEN standards
DeliveryUAE-wide, fast delivery, commissioning included
BMS Integration

Every Transformer Monitored 24/7 via BMS

Intellicon integrates every transformer with the site BMS via Modbus or BACnet. Winding temperature, load %, input/output voltage, and alarm states are trended every 30 seconds — displayed on the same dashboard as cooling, UPS, and power quality data.

  • Winding temperature trending and overtemperature alarm
  • Load % monitoring with demand forecasting
  • Input/output voltage and frequency logging
  • Auto-generated monthly transformer health reports
  • SMS + email alert to FM team within 90 seconds of fault

Get a Transformer Specification for Your Data Centre

Our engineers specify, King Link manufactures, and Intellicon commissions — complete service from single-line diagram to BMS handover. UAE-wide delivery and installation.

Request SpecificationAll Solutions